Background Image
Table of Contents Table of Contents
Previous Page  272 / 30 Next Page
Information
Show Menu
Previous Page 272 / 30 Next Page
Page Background

30°С

в час

24

272

50°С

в час

100°С

в час

OPERATIONAL GUIDELINE OF THE CRUCIBLES

Storage of the Crucibles

Transportation

The crucibles should be stored in dry well-aired room, on wood

shelving (supports). The storage of the crucibles on concrete or

metal floor is not allowed.

It is not allowed to put the crucibles one into another.

It is impossible to enable pushes and impacts on the crucibles.

It is impossible tо move the crucibles on floor edgewise or on

the bottom edge.

It is recommended to use the trolleys with padding transportation.

Preparation of crucibles

Glowing of crucibles

- crucibles of type C - rise of temperature till 900°C in 50°C per hour.

- crucibles of type A and K - rise of temperature till 1050°C in 100°C

per hour.

- crucibles of type X - rise of temperature till 400°C in 100°C per hour

and further till 1050°C as soon as possible.

Drying of crucibles

- at temperature 200 C 24 hours at least. The rise of

temperature should not be sudden at most 30°C per hour.

°